Product Description

Product Parameters

Input( DC)

Type designation
SG33CX
SG40CX
SG50CX
SG110CX
Max. PV input voltage
1100 V
Min. PV input voltage / Start-up input voltage
200 V / 250 V
Nominal PV input voltage
585 V
MPP voltage range
200 - 1000 V
MPP voltage range for nominal power
550 - 850V
No. of independent MPP inputs
3
4
5
9
Max. number of PV strings per MPPT
2
2
2
2
Max. PV input current
78 A
104 A
130 A
26 A * 9
Max. DC short-circuit current
120 A
160 A
200 A
40 A * 9

Output (AC)

Type designation
SG33CX
SG40CX
SG50CX
SG110CX
AC output power
33 kVA @45 ºC, 400Vac / 36.3 kVA @ 40 ºC,400Vac 33 KVA@50 ºC, 415Vac / 36.3 KVA@45 ºC, 415Vac
40 kVA @45 ºC, 400Vac / 44 kVA @ 40 ºC,400Vac 40 KVA@50 ºC, 415Vac / 44 KVA@45 ºC, 415Vac
50 kVA @45 ºC, 400Vac / 55kVA @ 40 ºC,400Vac 50KVA@50 ºC, 415Vac / 55kVA @ 45 ºC,415Vac (Australia: max. 50 kVA)
110 kVA @ 45 ºC / 100 kVA @ 50 ºC
Max. AC output current
55.2 A
66.9 A
83.6 A
158.8 A
Nominal AC voltage
3 / N / PE, 230 / 400 V
AC voltage range
312 - 528 V
320 - 460 V
Nominal grid frequency / Grid frequency range
50 Hz / 45 - 55 Hz, 60 Hz / 55 - 65 Hz
THD
< 3 % (at nominal power)
DC current injection
< 0.5 % In
Power factor at nominal power / Adjustable power factor
> 0.99 / 0.8 leading - 0.8 lagging
Feed-in phases / connection phases
3 / 3
Max. efficiency / European efficiency
98.6 % / 98.3 %
98.6% / 98.3%
98.7% / 98.4%
98.7 % / 98.5%

General Data

Type designation
SG33CX
SG40CX
SG50CX
SG110CX
Dimensions (W*H*D)
702*595*310mm
782*645*310mm
782*645*310mm
1051*660*362.5 mm
Weight
50 kg
58 kg
62 kg
89 kg
Isolation method
Transformerless
Degree of protection
IP66
Night power consumption
≤2 W
Operating ambient temperature range
-30 to 60 ºC
Allowable relative humidity range (non-condensing)
0 - 100 %
Cooling method
Smart forced air cooling
Max. operating altitude
4000 m (> 3000 m derating)
Display
LED, Bluetooth+APP
Communication
RS485 / Optional: Wi-Fi, Ethernet
DC connection type
MC4 (Max. 6 mm²)
AC connection type
OT or DT terminal (Max.70 mm²)
OT / DT terminal (Max. 240 mm²)
Compliance
IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N 4105:2018, VDE-AR-N 4110:2018, IEC 61000-6-3, EN 50549, AS/NZS
4777.2:2015, CEI 0-21, VDE 0126-1-1/A1 VFR 2014, UTE C15-712-1:2013, DEWA
Grid Support
Q at night function, LVRT, HVRT,active & reactive power control and power ramp rate control

Detailed Photos

 

Packaging & Shipping

What we provide

Contact

Supply Ability

--

Packaging and Shipping

Lead time

--

Port

--

Packaging details

--


Comments
Welcome to zddshop comments! Please keep conversations courteous and on-topic. To fosterproductive and respectful conversations, you may see comments from our Community Managers.
Sign up to post
Sort by
Show More Comments

Other offers of this wholesaler

Copyright 2023-2024 - www.zddshop.com All Rights Reserved