zddshop
/
Product
/
Solar Energy Products
/
Solar on Grid Solar Inverter for Rooftop Solar Plant

Solar on Grid Solar Inverter for Rooftop Solar Plant

$200 /piece price excl.VAT

Negotiable
Order

Minimal order
100 pieces

Message Phone call

Product Specifications

Type

DC/AC Inverters

Product Description

NEP Micro solar inverter--24 hours monitoring on nepviewer website

Solar on grid tie inverter pure sun wave micro inverter ---250w

The nep company was founded in 2009.We have three research center around USA,JAPAN and China.

We have the advantages in making the 250w solar inverter,300w solar inverter and 600w solar inverter.

Advantages:

MUCH SAFER

ACPV Systems are the safest choice for generating solar rooftop power as unlike traditional DC-based string/central inverters which have a high DC voltage of up to 600V running through their DC cables, AC systems are less likely to sustain Arc faults (a major cause of PV fires) due to the internal DC voltage being only that of a single PV module.

 

FASTER INSTALL

Micro Inverter based systems take up to to 50% less time to install when compared to string based DC systems. As micro inverters are integrated onto the Solar modules and arrive at a job site ready to install, no DC cabling in conduit is required, significantly reducing installation cost and complexity.

 

MORE DEPENDABLE

The micro inverter is highly reliable as it is designed to operate from -40C to +85C, achieves a peak efficiency of 94.1% and has a 25 year life expectancy to match solar panels. Micro inverters are more dependable through the elimination of the central inverter, which typically requires replacing at least once in a system's lifetime.

 

MORE PERFORMANCE

Micro inverters allow each solar panel to operate independently and control the power from each with 99.6% accuracy. This results in a significant increase in the performance of the entire system over a single inverter system (see images below). You can also monitor the performance of each AC module online.

24 hours monitoring system:

 

By connecting micro inverters with NEP communications gateway BDG-256, Customers, distributors and installers could monitor the energy generation at any time and at any place.

Packing:

 

One piece of BDM-250

        Weight: 2.5kg

      

One carton box (10 pics)

              Weight: 27.5kg

           Volume: 0.43*0.34*0.48M

300w solar micro inverter specification data:

Grid-tie Micro inverter systemBDM300W                                                          Grid-tie Micro inverter                                                                                                  

                                 ModelBDM-250-240ABDM-250-208ABDM-250-EU
BDM-250-AU
Input(DC)Max Recommended PV Power (Wp)                              285

Max DC Open Circuit Voltage(Vdc)                                 60

Max DC Input Current(Adc)                                12

MPPT Tracking Range(Vdc)                              22-55

MPPT Tracking Accuracy                              99.5%

Maximum Inverter Backfeed current to the array                              0
OUTPUT(AC)Rated AC Output Power(Vac)240208230

Allowable Power Grid Voltage(Vac)211-264183-229configurable

THDless than 3% at rated power

Current maximum continuous Aac1.21.21.2

Current  inrush peak and duration                         12A,15us
System EfficiencyPeak efficiency96.3%

CEC efficiency95%
Protection FunctionsOver/Under Voltage Protection Yes

Over/Under  Frequency Protection Yes

Anti-islanding protection Yes

Over Current Protection Yes

Reverse DC Polartity Protection Yes

Overload Protection Yes
Other ParametersEnvironment Temperature-40-+65 degree

Protection degareeIP67

Dimention180*186*25

Weight1.5kgs

CommunicationPower line

Environment CategoryIndoor and outdoor

Pollution DegreePD3
Product Safety ComplianceUL1741  CSA C22.2 No.107.1IEC/EN 62109-1
IEC/EN 62109-2
Grid Code Compliance Refer to the label for the detailed grid code complianceIEEE1547VDE-AR-N 4105
VDE V 0126-1-1/A1
G83/2,CEI021
AS4777.2&AS4777.3

Note:

For grid code VDE-AR-N 4105,maximum3.68KVA pv plant is limited.The grid protection report and setting

are readable fro the gateway.

For grid code G83/2,MAXIMUM 16a per phase is limited.The grid protection report and setting are readable

from the gateway.

Grid parameters are configurable through the BDG-256 gateway.

 

 

Supply Ability

--

Packaging and Shipping

Lead time

--

Port

--

Packaging details

--


Comments
Welcome to zddshop comments! Please keep conversations courteous and on-topic. To fosterproductive and respectful conversations, you may see comments from our Community Managers.
Sign up to post
Sort by
Show More Comments

Other offers of this wholesaler

Copyright 2023-2025 - www.zddshop.com All Rights Reserved