Ready to ship without MOQ MUST POWER Big PV power inverter 12kw MUST PV35 5kw solar inverter frequency converter 50hz to 60hz off grid inverter
- Minimal order
- 100 pieces
Message Phone call
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin: Guangdong, China
Brand Name: MUST, MUST
Model Number: PV3500 5-15K, PV3500 5-15K
Input Voltage: 100v/110v/120v/220v/230v
Output Voltage: 100v/110v/120v/220v/230v
Output Current: 45/60A, 30A-100A
Output Frequency: 50-60 HZ
Output Type: Single
Size: 505*701*330mm
Type: DC/AC Inverters
Weight: 40-70kgs
Color: Red or Greem or OEM
Display: LCD+LED display
MPPT max efficiency: 98%
Rated charge current: 100A
Audible Noise: 60db
Warranty: one year
Packaging & Delivery
Off gird Pure sine wave inverter 8kw 10kw 12kw 48v hybrid solar inverter with MPPT 80A charger for solar power system
Off gird Pure sine wave inverter 8kw 10kw 12kw 48v hybrid solar inverter with MPPT 80A charger for solar power system
MUST PV35 Off gird Pure sine wave invert 8kw 10kw 12kw 48v hybrid solar inverter MUST PV35 5kw solar inverter frequency converter 50hz to 60hz off grid inverter
Pure sine wave inverter charger 8kw 10kw 48v hybrid solar inverter with MPPT charger for solar power system for home and government
Quality assured 5kw solar energy power inverter with LED display
- Power range 5KVA-15KVA;
- 24V/48VDC input voltage;
- Powerful charge reate up tp 100Amp;
- Pure sine wave output;
- LED + LCD display;
- MPPT solar charge controller 40A 45A 60A;
- MPPT effeciency may 98%;
- RS232 with free CD;
- Battery priority function;
- High efficiency design & " power saving mode" to conserve energy.
Products show
The specification
Model | PV35-5K | PV35-6K | PV35-7500 | PV35-10K | PV35-12.5K | PV35-15K | ||||
Default Battery System Voltage | 24V DC | 48V DC | 24V DC | 48V DC | 24V DC | 48V DC | 48V DC | 48V DC | 48V DC | |
INVERTER OUTPUT | Continuous output power | 5KVA/ 4.0KW | 8KVA/ 4.8KW | 7.5KVA/ 6.0KW | 10KVA/ 8.0KW | 12.5KVA/ 10.0KW | 15KVA/ 12.0KW | |||
Surge rating (20ms) | 12.0KW | 15.0KW | 18.0KW | 24.0KW | 30.0KW | 36.0KW | ||||
Capable of starting electric motor | 2HP | 3HP | 3HP | 4HP | 5HP | 6HP | ||||
Output waveform | Pure sine wave/ same as input (bypass mode) | |||||||||
Inverter efficiency (Peak) | >88% | |||||||||
Line mode efficiency | >95% | |||||||||
Power factor | 0.8 | |||||||||
Nominal output voltage RMS | 220V/230V/240VAC(+/-10% RMS) | |||||||||
Output frequency | 50Hz/60Hz +/-0.3 Hz | |||||||||
Short circuit protection | Yes(1sec after fault) | |||||||||
Typical transfer time | 10ms(max) | |||||||||
AC INPUT | Voltage | 230VAC | ||||||||
Selectable voltage range | 155~280VAC(For Personal Computers) | |||||||||
Frequency range | 50Hz/60Hz (Auto sensing) 40-80Hz | |||||||||
BATTERY | Minimum start voltage | 20.0VDC/21.0VDC for 24VDC mode (40.0VDC/42.0VDC for 48VDC mode) | ||||||||
Low battery alarm | 21.0VDC+/-0.3V for 24VDC mode (42.0VDC+/-0.6V for 48VDC mode) | |||||||||
Low battery cutoff | 20.0VDC+/-0.3V for 24VDC mode (40.0VDC+/-0.6V for 48VDC mode) | |||||||||
High voltage alarm | 32.0VDC+/-0.3V for24VDC mode (64.0VDC+/-0.6V for 48VDC mode) | |||||||||
High battery voltage recover | 31.0VDC+/-0.3V for 24VDC mode (62.0VDC+/-0.6V for 48VDC mode) | |||||||||
Idle Consumption Search Mode | <25W when power saver on | |||||||||
AC CHARGER | Output Voltage | Depends on battery type | ||||||||
Charger AC Input Breaker Rating | 30A | 30A | 30A | 40A | 50A | 63A | ||||
Max charge power rating | 1/3 Rating power | |||||||||
Overcharge Protection S.D. | 31.4VDC for 24VDC mode(62.8VDC for 48VDC mode) | |||||||||
Maximum Charge Current | 65A | 35A | 65A | 40A | 65A | 50A | 70A | 80A | 100A | |
BTS | Continuous Output Power | Yes Variances in charging voltage & S.D. voltage base on the battery temperature | ||||||||
BYPASS & PROTECTION | Input Voltage Waveform | Sine wave (grid or generator) | ||||||||
Nominal voltage | 220V/230V/240VAC | |||||||||
Max input AC voltage | 300VAC for 230VAC HV mode | |||||||||
Nominal input frequency | 50Hz or 60Hz | |||||||||
Overload Protection (SMPS Load) | Circuit breaker | |||||||||
Output Short Circuit Protection | Circuit breaker | |||||||||
Bypass Breaker Rating | 40A | 40A | 40A | 50A | 63A | 63A | ||||
Max Bypass Current | 40Amp | 80Amp | ||||||||
Rated voltage | 24VDC/48VDC | |||||||||
PV open circuit voltage | Operational max =145VDC temperature corrected VOC | |||||||||
SOLAR CHARGER | Maximum PV Charge Current | 60A | 60A(120A Optional) | |||||||
DC Voltage | 24V/48V atuo work | 48V | ||||||||
Maximum PV Array Power | 1600 W | 3200 W | 1600 W | 3200 W | 1600 W | 3200 W | 3200W(6400W for 120A Optional) | |||
MPPT Range @ Operating Voltage(VDC) | 32-145VDC FOR 24V mode, 64-145V for 48V mode | 64-145VDC | ||||||||
Maximum PV Array Open Circuit Voltage | 147VDC | 147VDC | ||||||||
Maximum Efficiency | >98% | |||||||||
Standby Power Consumption | <2W | |||||||||
MECHANICAL SPECIFICATIONS | Mounting | Wall mount | ||||||||
Dimensions (W*H*D) | 414*575*211mm | 414*645*211mm | ||||||||
Net Weight (Solar CHG) kg | 38+2.5 | 48+2.5 | 49+2.5 | 60+2.5 | 66+2.5 | 70+2.5 | ||||
Shipping Dimensions (W*H*D) | 505*701*330mm | 505*771*330mm | ||||||||
Shipping Weight (Solar CHG) kg | 40+2.5 | 50+2.5 | 51+2.5 | 62+2.5 | 68+2.5 | 72+2.5 | ||||
OTHER | Operation Temperature Range | 0°C to 40°C | ||||||||
Storage Temperature | -15°C to 60°C | |||||||||
Audible Noise | 60dB MAX | |||||||||
Display | LED+LCD | |||||||||
Loading (20GP/40GP/40HQ) | 140pcs/280pcs/320pcs |
Supply Ability
--
Packaging and Shipping