MUST EP3300 TLV Series 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW battery management system for lead acid ups bypass switch
- Minimal order
- 100 pieces
Message Phone call
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin: Guangdong, China
Brand Name: MUST
Model Number: EP3300 TLV Series
Input Voltage: 220Vac / 230Vac / 240Vac
Output Voltage: 100V / 110V / 120VAC(200V / 220V / 240VAC)±10%
Output Current: 9A-54A (4.5A-27A)
Output Frequency: 50HZ/60HZ
Output Type: Single
Size: 277*196*466mm to 277*186*621mm
Type: DC/AC Inverters
Inverter Efficiency: >80%
Certificate: CE etc.
Warranty: 12month
Weight: 20kg-30kg
Brand: MUST
Power Factor: 1
Rated Power: 1KW-6KW
Surge Rating: 3kva-18kva
Waveform: Pure sine wave
AC input voltage: 220Vac / 230Vac / 240Vac
Battery Minimum Start Voltage: 11VDC/22VDC/44VDC
Typical Transfer Time: 15ms(max)
Low Battery Cutoff: 10/10.5/11V for 12V model(*2 for 24DVC / *4 for 48VDC)
Display: LCD
Supply Ability
Supply Ability: 10000 Piece/Pieces per Month
Packaging & Delivery
MUST EP3000 Pro Series 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW solar inverter pure sine wave inverter low frequency power inverter
solar inverter
off grid inverter
Pure Sine Wave Inverter
This split phase inverter EP3300 TLV series, capacity from 1KW-6KW, DC 12V/24V/48V, it’s applicable to 110VAC/120VAC markets demands, which matches AC 110VAC/120V single phase, or two phase 110VAC/120V 120V/240V; In LCD display, you can set output voltage, frequency, charging voltage, charging current to design best use based on different loads applications; meanwhile, you can also connect extra solar charger controller to build a solar home system, take use of sunshine freely and save electricity bills.
1.Pure sine wave output, split phase HOT1+ N + HOT2 available, 120VAC/220VAC
2.MFD (multi-function display) & Friendly user interface
3.3 Steps optimizing charge for battery pack
4.Overload and short-circuit protection
5.Settable: charging/charging current, utility/Battery priority, utility input wide/narrow range
6.Inverter voltage can be set to 100V/110V/120V
7.Inverter frequency can be set to 50/60Hz
Model | EP33-1012TLV | EP33-1024TLV | EP33-1512TLV | EP33-1524TLV | EP33-2012TLV | EP33-2024TLV | EP33-3024TLV | EP33-3048TLV | EP33-4024TLV | EP33-4048TLV | EP33-5048TLV | EP33-6048TLV |
Inverter Output | ||||||||||||
Rated power(W) | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |||||
Power Factor | 1 | |||||||||||
Wave form | Pure sine wave/ Same as input waveform (bypass mode) | |||||||||||
Output voltage RMS | 100V/110V/120VAC(200V/220V/240VAC)±10% | |||||||||||
Output frequency | 50HZ or 60HZ (±0.3HZ) (can be set) | |||||||||||
Overload protection | Breaker + software protection | |||||||||||
Output short circuit | Breaker + software protection | |||||||||||
Inverter efficiency(peak) | >80% | |||||||||||
Overload | 100%<Load<110% (alarm 5min then stop output and fault code 07); 110%<Load<125% (alarm 60s then stop output and fault code 07); Load>125% (alarm 10s then stop output and fault code 07) | |||||||||||
Surge rating | 3000VA | 4500VA | 6000VA | 9000VA | 12000VA | 15000VA | 18000VA | |||||
Capable of starting electric motor | 1P | 1P | 1.5P | 1.5P | 2P | 3P | ||||||
Battery | ||||||||||||
Battery voltage | 12VDC/24VDC | 24VDC/48VDC | 48VDC | |||||||||
Minimum start voltage | 11VDC/22VDC/44VDC | |||||||||||
Low battery voltage cut off | (low voltage fault code04)10/10.5/11V for 12V model(*2 for 24DVC / *4 for 48VDC) | |||||||||||
Low battery voltage alarm | Add 0.5V/battery: (low battery alarm one second one time) (10/10.5/11V) + 0.5Vdc for 12V model(*2 for 24DVC / *4 for 48VDC) | |||||||||||
High battery voltage alarm | Add +1V/battery: (high voltage one second one time/after 30s fault 03) (13.8-14.5V) + 1V for 12V model(*2 for 24DVC / *4 for 48VDC) | |||||||||||
Save mode | Load≤40W(110V)/80W(220V) | |||||||||||
AC Input Mode | ||||||||||||
Input waveform | Pure sine wave | |||||||||||
Nominal input voltage | 220Vac / 230Vac / 240Vac | |||||||||||
Max input voltage | 270Vac MAX | |||||||||||
Input frequency | 50HZ/60HZ (auto sensing) | |||||||||||
Efficiency(AC mode) | >95% (load, full battery) | |||||||||||
Transfer time AC TO DC | 15ms(max) | |||||||||||
Transfer time DC TO AC | 15ms(max) | |||||||||||
Charge Mode | ||||||||||||
Boost Voltage | 14.1V(Default) Range of adjustment 13.8-14.5V/*2 for 24VDC/*4 for 48VDC (Regulation step 0.1V) | |||||||||||
Float Voltage | 13.5V(default) Range of adjustment 13.5-13.7V/*2 for 24VDC/*4 for 48VDC (Regulation step 0.1V) | |||||||||||
12V | 30A | 45A | 60A | |||||||||
24V | 20A | 25A | 30A | 40A | 60A | |||||||
48V | 20A | 30A | 35A | 40A | ||||||||
Min charge current 10A. change by every 5A. | ||||||||||||
Dimensions | ||||||||||||
Dimensions (W*H*D) | 277*196*466mm | 277*186*621mm | ||||||||||
Ship Dimensions (W*H*D) | 376*306*592mm | 376*296*747mm | ||||||||||
Warranty | One year(standard),2years optional(IP20) |
*Products specifications are subject to change without further notice
Packaging & Shipping
Our Services
Company Information
FAQ
Q1: How to choose a right inverter?
A1:Tell us your demand, then our sales will recommend a suitable inverter to you.
Q2: What's the different between inverter and solar inverter?
A2: Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accept PV input, it more save power.
Q3: How about the delivery time?
A3: 7 days for sample; 25 days for bulk order.
Q4: What is the warranty of inverter?
A4: One year warranty on Must-Solar product.
Q5: How to solve the technical problem?
A5: 24 hours after-service consultancy just for you and to make your problem to solve easily.
Supply Ability
--
Packaging and Shipping
Lead time
--
Port
--
Packaging details
--