Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin: Guangdong, China
Brand Name: MUST
Model Number: EP3000 Pro Series
Input Voltage: 230VAC
Output Voltage: 100V-240V
Output Current: 10A-25A
Output Frequency: 5OHz/60Hz
Output Type: Single
Size: 426*206*178 mm to 601*206*178
Inverter Efficiency: >88%
Certificate: CE etc.
Warranty: 12 month
Weight: 16-45kg
Brand: MUST
Power Factor: 1.0
Rated Power: 1-6KW
Surge Rating: 3KVA-18KVA
Waveform: Pure sine wave/ same as input (bypass mode)
AC input voltage: 230VAC
Battery Minimum Start Voltage: 10.0VDC /10.5VDC for12VDC mode (*2 for 24VDC,
Typical Transfer Time: 10ms
Low Battery Cutoff: 10.0VDC±0.3V for12VDC mode (*2 for 24VDC, )
Display: LED+LCD
Supply Ability
Supply Ability: 10000 Piece/Pieces per Month
Packaging & Delivery
MUST EP3000 Pro Series1KW 1.5KW 2KW 3KW 4KW 5KW 6KW solar inverter pure sine wave inverter low frequency power inverter
EP3000 Pro series is very economical pure sine wave inverter , AC charger inbuilt , from 35A to 70A ; Solar /AC priority is configurable, When setting solar priority , solar will charge batteries as first priority , and AC can also charge batteries when solar charge current too lower , in this way system charge is optimazed best . With pure copper transformer , it enables inverter to operate with all kinds of home appliances .
Feature
1.LCD display , easy to read how inverter operates on LCD screen
2.Compatible to generator
3.5-levels DIP switch , offering customized performance
4.9-levels battery selector , Enable to charge Li-thium , Gel , lead-acid battery
5.DC(Solar)/AC prority optional
6.4 levels charge current adjustable
7.With RS232 communication port
8.With BTS & GTS , optimazing battery performance & start generator automatically
9.Power saver Switch , Enable to minimize standby consumption
Technical Specificat
MODEL | EP30-1KW PRO | EP30-1.5KW PRO | EP30-2KW PRO | EP30-3KW PRO | EP30-4KW PRO | EP30-5KW PRO | EP30-6KW PRO | ||||||||
Default Battery System Voltage | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 48VDC | 24VDC | 48VDC | 24VDC | 48VDC | 24VDC | 48VDC |
INVERTER OUTPUT | |||||||||||||||
Reted Power | 1.0KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | ||||||||
Surge Rating (20ms) | 3.0KVA | 4.5KVA | 6.0KVA | 9.0KVA | 12KVA | 15KVA | 18KVA | ||||||||
Capable Of Starting Electric Motor | 1HP | 1HP | 1HP | 2HP | 3HP | ||||||||||
Waveform | Pure sine wave/ same as input (bypass mode) | ||||||||||||||
Nominal Output Voltage RMS | 100V/110V/120VAC 220V/230V/240VAC(±10% RMS) | 220V/230V/240VAC(±10% RMS) | |||||||||||||
Output Frequency | 5OHz/60Hz±0.3 Hz | ||||||||||||||
Inverter Efficiency(Peak) | >88% | ||||||||||||||
Line Mode Efficiency | >95% | ||||||||||||||
Power Factor | 1 | ||||||||||||||
Typical Transfer Time | 10ms(max) 10ms(max) | ||||||||||||||
AC INPUT | |||||||||||||||
Voltage | 230VAC | ||||||||||||||
Selectable Voltage Range | 96~132VAC 155~280VAC(For Personal Computers) | ||||||||||||||
Frequency Range | 50Hz/60Hz (Auto sensing) 40~80Hz | ||||||||||||||
BATTERY | |||||||||||||||
Minimum Start Voltage | 10.0VDC /10.5VDC for12VDC mode (*2 for 24VDC, ) | ||||||||||||||
Low Battery Alarm | 10.5VDC±0.3V for12VDC mode (*2 for 24VDC, ) | ||||||||||||||
Low Battery Cutoff | 10.0VDC±0.3V for12VDC mode (*2 for 24VDC, ) | ||||||||||||||
High Voltage Alarm | 16.0VDC±0.3V for12VDC mode (*2 for 24VDC, ) | ||||||||||||||
High Battery Voltage Recover | 15.5VDC±0.3V for12VDC mode (*2 for 24VDC, ) | ||||||||||||||
Idle Consumption-Search Mode | <25W when power saver on | ||||||||||||||
CHARGER | |||||||||||||||
Output Voltage | Depends on battery tvpe | ||||||||||||||
Charger AC Input Breaker Rrating | 10A | 30A | 30A | 30A | 40A | ||||||||||
Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC mode) | ||||||||||||||
Maximum Charge Current | 35A | 20A | 45A | 25A | 65A | 35A | 75A | 45A | 30A | 65A | 35A | 70A | 40A | 75A | 50A |
BYPASS & PROTECTION | |||||||||||||||
Input Voltage Waveform | Sine wave (grid or generator) | ||||||||||||||
Nominal Input Frequency | 50Hz or 60Hz | ||||||||||||||
Overload Protection (SMPS Load) | Circuit breaker | ||||||||||||||
Output Short Circuit Protection | Circuit breaker | ||||||||||||||
Bypass Breaker Rating | 10A | 30A | 30A | 30A | 40A | ||||||||||
Max Bypass Current | 30Amp | ||||||||||||||
MECHANICAL SPECIFICATIONS | |||||||||||||||
Mounting | Wall mount | ||||||||||||||
Dimensions (W*H*D) | 426*206*178 mm | 601*206*178 | |||||||||||||
Net Weight (Solar CHG) kg | 16.5 | 17 | 21.1 | 20 | 26 | 24.5 | 24.8 | 38.2 | 35.8 | 45.2 | 45 | 45.2 | 45 | ||
Shipping Dimensions(W*H*D) | 570*335*300mm | 750*335*300mm | |||||||||||||
Shipping Weight (Solar CHG) kg | 19.3 | 20 | 24.1 | 22.8 | 29.1 | 27.5 | 27.5 | 42.3 | 40 | 49.5 | 49.3 | 49.5 | 49.3 | ||
OTHER | |||||||||||||||
Operation Temperature Range | 0°C to 40°C | ||||||||||||||
Storage Temperature | -15°C to 60°C | ||||||||||||||
Audible Noise | 60dB MAX | ||||||||||||||
Display | LED+LCD | ||||||||||||||
Standard Warranty | 1 year,2 or 3 years optional(IP20) |
*Products specifications are subject to change without further notice
Packaging & Shipping
Our Services
Company Information
FAQ
Q1: How to choose a right inverter?
A1:Tell us your demand, then our sales will recommend a suitable inverter to you.
Q2: What's the different between inverter and solar inverter?
A2: Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accept PV input, it more save power.
Q3: How about the delivery time?
A3: 7 days for sample; 25 days for bulk order.
Q4: What is the warranty of inverter?
A4: One year warranty on Must-Solar product.
Q5: How to solve the technical problem?
A5: 24 hours after-service consultancy just for you and to make your problem to solve easily.
Supply Ability
--
Packaging and Shipping
Lead time
--
Port
--
Packaging details
--