MPPT 12V24V20A LCD Solar Charge Controller
$56
/piece
price excl.VAT
Negotiable
- Minimal order
- 100 pieces
Message Phone call
Product Specifications
--
Product Description
System voltage | Vmp Min | Vmp suggested value | Vmp Max |
12V | 15V | 18V | 25V |
24V | 30V | 36V | 45V |
Battery voltage | Undervoltage point | Undervoltage recovery point | Floating point | Overpressure recovery point | Over pressure point |
12V System | 10.5V | 12.0V | 14.0V | 13.5V | 15.0V |
24V System | 20.0V | 24.0V | 28.0V | 27.0V | 30.0V |
Output Function Settings
Each outut rated current | 5A |
Rated power per output(12V/24V) | 60W/100W |
MODE:Street light mode | Light control on;Light control off;Light control point 6V(adjustable) |
MODE:Street light mode+City electricity switch function | Light control on;Light control off;Light control point 6V(adjustable) |
MODE:Monitoring mode | 24-hour output |
MODE:Monitoring mode+City electricity switch function | 24-hour output |
Performance
Photovoltaic open circuit maximum voltage | ≤60V(Voc) |
Battery voltage | Minimum 9V (12V battery); minimum 18V (24V battery) |
Rated charge curreent | *10A *20A *30A |
Static power | ≤15mA |
Power conversion efficiency | ≥95% |
Maximum current per output | 8A |
Temperature compensation | 25 °C as the standard, for every 1 °C decrease, the overvoltage point is increased by 30mV |
Radiated method | The overall chassis cooling, natural cooling |
Working temperature | -30ºC ~ +55ºC |
Humidity range | Relative humidity of air is not more than 85%(25ºC±5ºC) |
Working altitude | ≤2000 |
Waterproof level | IP52 |
Net weight | 0.6kg |
Troubleshootings
Fault phenomenon | Possible Causes | Solution |
The controller is installed for the first time and does not work | 1.The battery voltage is too low 2.The battery reverse | 1.Replace the new battery or use other methods to charge first 2.Please adjust the correct connection |
The controller does not charge when there are direct solar cell components | 1.Photovoltaic cell array connection open circuit 2.The battery experienced overcharge point,has not yet dropped to restore charge point | 1.Please check whether the connection of the teo ends of the photovoltaic battery power is correct and whether the contact is reliable 2.Please use the inverter for discharge |
Small charging current | 1.Light intensity is not strong 2.The battery is close to satyration,in the floating state | 1.Observe when the sun is strong 2.Normal |
LED display over-discharge | Battery undervoltage | Display "normal" after sufficient power |
LED display over-charge | Battery overvoltage | Display "normal" after power down |
Supply Ability
--
Packaging and Shipping
Lead time
--
Port
--
Packaging details
--
Comments
Welcome to zddshop comments! Please keep conversations courteous and on-topic. To fosterproductive and respectful conversations,
you may see comments from our Community Managers.
Sign up to post
Show More Comments