Mars Rock 1000W 10.5 - 50V DC to AC 90 - 140V or 190 - 260V Energy Meter Wind Grid Tie Airconditioner Air Conditioner Inverter
- Minimal order
- 100 pieces
Message Phone call
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin: Fujian,China
Brand Name: Mars Rock
Model Number: GTI1000
Input Voltage: Vmp@18V(10.5-30VDC); Vmp@36V(20-50VDC);
Output Voltage: @120V(90-140V); @230V(190-260V)
Output Current: 9.1A(@120V); 4.5A(@230V);
Output Frequency: Auto match frequency: 50/60Hz(48-65Hz)
Output Type: Single, Triple
Size: 39.5*21*11.5CM
Type: DC/AC Inverters
Inverter Efficiency: 88%
Certificate: FCC, CE, ROHS, CE, RoHS, FCC
Warranty: 1 year
Weight: 2.6KGS
Product name: Energy Meter Wind Grid Tie Airconditioner Air Conditioner Inverter
Suggest Solar: >1200W
Max Output: 1000W
DC Input: 18V(10.5-30VDC) or 36V(20-50VDC)
AC Output: 120V(90-140VAC) or 230V(190-260VAC)
Stand-by Power: <1W
Protection: Islanding; Short-circuit; low and over voltage; High temperature
Grid distrubance: EN 50178/ EN 62109-1 /VDE 0126-1-12
Showing: Luminous diode(LED)
Supply Ability
Supply Ability: 30000 Piece/Pieces per Month
Packaging & Delivery
#detail_decorate_root .magic-0{border-bottom-style:solid;border-bottom-color:#53647a;font-family:Roboto;font-size:24px;color:#53647a;font-style:normal;border-bottom-width:2px;padding-top:8px;padding-bottom:4px}#detail_decorate_root .magic-1{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-2{width:750px}#detail_decorate_root .magic-3{overflow:hidden;width:750px;height:750px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-4{margin-top:0;margin-left:0;width:750px;height:750px}#detail_decorate_root .magic-5{vertical-align:top}#detail_decorate_root .magic-6{padding:0;margin:0;color:#333;font-size:14px;padding-left:4px;font-weight:bold;white-space:pre-wrap}#detail_decorate_root .magic-7{font-size:20px}#detail_decorate_root .magic-8{font-size:18px}#detail_decorate_root .magic-9{vertical-align:top;display:block;padding-right:4px;box-sizing:border-box;padding-left:4px}#detail_decorate_root .magic-10{vertical-align:top;padding-bottom:4px;box-sizing:border-box;padding-top:4px}#detail_decorate_root .magic-11{padding:0;margin:0;white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-13{font-size:16px}#detail_decorate_root .magic-14{width:750px;border-collapse:collapse}#detail_decorate_root .magic-15{min-height:18px;padding:5px 10px;width:89px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-16{min-height:18px;padding:5px 10px;width:125px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-17{display:none}#detail_decorate_root .magic-18{min-height:18px;padding:5px 10px;width:52px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-19{min-height:18px;padding:5px 10px;width:119px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-20{min-height:18px;padding:5px 10px;width:48px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-21{min-height:18px;padding:5px 10px;width:115px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-22{min-height:18px;padding:5px 10px;width:34px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-23{min-height:18px;padding:5px 10px;width:131px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-24{min-height:18px;padding:5px 10px;width:61px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-25{min-height:18px;padding:5px 10px;width:554px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-26{min-height:18px;padding:5px 10px;width:49.273px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-27{min-height:18px;padding:5px 10px;width:32px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-28{min-height:18px;padding:5px 10px;width:49px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-29{min-height:18px;padding:5px 10px;width:45px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-30{min-height:18px;padding:5px 10px;width:62.5454px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-31{min-height:18px;padding:5px 10px;width:24px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-32{min-height:18px;padding:5px 10px;width:58px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-33{min-height:18px;padding:5px 10px;width:664px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-34{min-height:18px;padding:5px 10px;width:407px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-35{overflow:hidden;width:750px;height:596.4630225080385px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-36{margin-top:0;margin-left:0;width:750px;height:596.4630225080385px}#detail_decorate_root .magic-37{overflow:hidden;width:750px;height:275.0272034820457px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-38{margin-top:0;margin-left:0;width:750px;height:275.0272034820457px}#detail_decorate_root .magic-39{overflow:hidden;width:750px;height:673.728813559322px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-40{margin-top:0;margin-left:0;width:750px;height:673.728813559322px}#detail_decorate_root .magic-41{overflow:hidden;width:750px;height:523.7068965517241px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-42{margin-top:0;margin-left:0;width:750px;height:523.7068965517241px}#detail_decorate_root .magic-43{overflow:hidden;width:750px;height:750px;margin-top:0;margin-bottom:4px;margin-left:0;margin-right:0}#detail_decorate_root .magic-44{overflow:hidden;width:373px;height:279.75px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-45{margin-top:-37px;margin-left:-32px;width:428px;height:320px}#detail_decorate_root .magic-46{overflow:hidden;width:373px;height:279.75px;margin-top:0;margin-bottom:0;margin-left:4px;margin-right:0}#detail_decorate_root .magic-47{margin-top:-17px;margin-left:-48px;width:473px;height:354px}#detail_decorate_root .magic-48{overflow:hidden;width:750px;height:367.26804123711344px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-49{margin-top:0;margin-left:0;width:750.0000000000001px;height:367.26804123711344px}#detail_decorate_root .magic-50{overflow:hidden;width:750px;height:561px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-51{margin-top:-10px;margin-left:-77px;width:907px;height:559px}#detail_decorate_root .magic-52{overflow:hidden;width:750px;height:1415.721649484536px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-53{margin-top:0;margin-left:0;width:750.0000000000001px;height:1415.721649484536px} Recommend Products
Product Description
Product Introduction.
1. Working principle
Smart grid tie inverter is a compact unit, which directly converts direct current into alternating current for powering appliances and office equipment and connecting to utility grid. The AC output from Smart micro inverter is synchronized and in-phase with the utility grid. It is a key device of power generation systems such as PV power generation system, wind turbine power generation system.
2. Matching solar panels
Smart micro inverter specially optimized design to work with modularization of DC power supplies which includes the mainstream solar modules, 18V (36 cells), 24V (60 cells) and 36V (72 cells) monocrystalline and/or Polycrystalline solar panels, wind turbines and batteries. Smart micro inverters are stabilization, reliable and high conversion efficiency items. It is the best choice for PV power generation systems.
3. MPPT technology
Smart micro inverter can be easily placed and attached to the rack underneath of PV module. No need spaces for independent installation and low voltage DC wire connects from the PV module to Smart micro inverter can eliminate the risk of high DC voltage. Distributed modularization design philosophy for Smart micro inverter insures the productiveness of the whole system and will not affect by a single point of failure. Each Smart micro inverter is individually connected to each PV module in the array. This unique configuration means that an individual Maximum Peak Power Point Tracker (MPPT) controls each PV modules and insures that the maximum power available from each PV module is exported to the utility grid regardless of the performance of the other PV modules in the array which may be affected by shading, soiling, orientation or mismatch, etc. Smart micro inverter insures top performance for maximizing energy production from the whole PV system and gets return on investment in less time.
4. Advantages of smart micro inverter
(1) Unique circuit design, choice of import industrial electronic components, higher efficiency, more stable performance.
(2) Creative MPPT technology, efficiency more than 99%, faster and more sensitive reaction, more reliable.
(3)Modular design, flexible combination and strong system expandability.
(4) Adopting high-frequency isolation transformer type, high efficiency, and high security.
(5) Perfect electrical protection function.
(6) Aluminum alloy housing, not rust, heat resistant and cold resistant as well as anti-corrosion.
(7) Getting electronic circuit design, appearance design and other core technology patents.
Details Images
Product Paramenters
Model | 1000W | 1200W | 1300W | 1400W | ||||||||||||
Suggest Solar | >1200W | >1400W | >1500W | >1700W | ||||||||||||
Max Output | 1000W | 1200W | 1300W | 1400W | ||||||||||||
Input Data | ||||||||||||||||
DC input | Vmp@18V(10.5-30VDC)/Solar cells=36 PCS per solar panel / MPPT Voltage: 18-21VDC; Vmp@36V(20-50VDC)/Solar cells=60/72 PCS per solar panel / MPPT Voltage: 24-45VDC | |||||||||||||||
@18V | @36V | @18V | @36V | @18V | @36V | @18V | @36V | |||||||||
Max Current | 62.5A | 40A | 75A | 48A | 81.5A | 52A | 87.5A | 56A | ||||||||
Output Data | ||||||||||||||||
Rated voltage | @120V(90-140VAC); @230V(190-260VAC) | |||||||||||||||
Auto match frequency: 50/60Hz(48-65Hz) | ||||||||||||||||
@120V | @230V | @120V | @230V | @120V | @230V | @120V | @230V | |||||||||
Rated current | 9.1A | 4.5A | 10.9A | 5.5A | 11.8A | 5.9A | 12.7A | 6.4A | ||||||||
Output Efficiency | ||||||||||||||||
Efficiency | @120VAC Verstion | |||||||||||||||
@18V | @36V | @18V | @36V | @18V | @36V | @18V | @36V | |||||||||
Peak Efficiency | 85% | 88% | 85% | 88% | 85% | 88% | 85% | 88% | ||||||||
Stable Efficiency | 83% | 86% | 83% | 86% | 83% | 86% | 83% | 86% | ||||||||
Efficiency | @230VAC Verstion | |||||||||||||||
@18V | @36V | @18V | @36V | @18V | @36V | @18V | @36V | |||||||||
Peak Efficiency | 88% | 88% | 88% | 88% | 88% | 88% | 88% | 88% | ||||||||
Stable Efficiency | 83% | 86% | 83% | 86% | 83% | 86% | 83% | 86% | ||||||||
Stand-by Power | <1W | |||||||||||||||
Feature | ||||||||||||||||
Power Transmission | Reverse transfer, load priority | |||||||||||||||
Protection | 1. Islanding; 2. Short-circuit; 3. DC & AC low voltge; 4. DC & AC over voltage; 5. High temperature | |||||||||||||||
Grid distrubance | EN 50178/ EN 62109-1 /VDE 0126-1-12 | |||||||||||||||
EMC | EN 61000-6-3:2007 / EN 61000-6-1:2007 | |||||||||||||||
Grid detection | DIN VDE 1026/UL1741 | |||||||||||||||
Certificate | CE, ROHS, FCC | |||||||||||||||
Exterior | ||||||||||||||||
Operation | - 20℃ to +65℃ | |||||||||||||||
Humidity | 0% to 90% Non-condensing | |||||||||||||||
Waterproof | IP23(Indoor design) | |||||||||||||||
Showing | Luminous diode(LED) | |||||||||||||||
Cooling | Electric fan(>45℃) | |||||||||||||||
Net Weight | @1000W | @1200W | @1300W | @1400W | ||||||||||||
2.1KGS | 2.1KGS | 2.2KGS | 2.2KGS | |||||||||||||
Gross Weight | 2.6KGS | 2.6KGS | 2.7KGS | 2.7KGS | ||||||||||||
Size (LxWxH) | 39.5x21x11.5CM | 39.5x21x11.5CM |
Installation Instructions
1. Grid-connecting of different power systems diagram:
(1) Grid-connecting in PV power system
(2) Wind-controller connection method
2. Grid-connecting in hybrid wind solar power system:
3. Grid-connecting in hybrid wind solar power system:(1) Parallel stacking in PV system.
(2) Grid-connecting way of selling electricity in PV system.
(3) Grid-connecting way of selling electricity in wind power system.
(4) Connect with 3 phase grid net.
Dear customers, If you want to know more instructions about the installation steps, welcome to contact me for more details.
Packaging and Shipping
Note: The AC Meter and fan are optional
Company Profile
MARS ROCK Group
We specialize in the development of green energy industry for more than 13 years. We own professional solar panel factory (FledaSolar Produce Co.,Ltd) in Shenzhen which can customize various solar panels for clients. Besides Solar panel, we expand our fields to wind turbine and solar water pump from 2015. Currently, our engineers' team can supply all solutions about solar, wind energy solutions to customers.
Quality First
Quality is the soul of products. Every order before shipping, products are tested at our lab first. Only qualfied products can
ship out. This is the secret of our yearly output has grown to over USD120,000,000. Customer First; Honesty First.
As a formal enterprise, customer is the source of our business. We believe "Customer is god" and we insist to do it. Honesty is the basic of doing business. Only honesty helps us to win more and more customers.
FAQ
Q1. How to match solar panel for my inverter?
Normally, buyers can choose solar panels according to the inverter's maximum output power of 1.2-1 .3 times. For example to 1 000W output inverter, to install 1200-1300W solar panel is reasonable.
Q2. If power from solar panel exceeds the power which guided on parameter sheet, will the inverter be burn out?
If the DC input voltage are in the guided range, for example: to @18V(10.5- -30V), @36V(20- -50), the inverter over current protection will be started, only within the safe and allowable DC voltage range, no matter how much the actual power generated by the solar panel, only the current of the maximum allowable output power of the inverter will be sent to the inverter, and other excess power will be restricted to produce in solar panel. That means solar panel only will produce the inverter max AC allowed output power(The power loss of the inverter must be added).
Q3. If my solar panel power is lower than User Manual parameter guidance, is it workable?
The workable condition is that:
(1) Both DC and AC sides' power are workable. That means only in day time with good sun light, and use local grid net with electrical power;
(2) DC input voltage to this inverter must be keep in the allowance scope @ 18V(10.5-30V, DC30V is solar panel Voc max voltage) @36V(20-50V, DC50V is solar panel Voc max voltage)
Q4. When i get this new inverter, how can i do the testing?
First, you can connect with grid through your home socket. If the AC side blue color LED lamp is lighting( on inverter’ s AC socket) . That means this inverter match with your local grid successfully.
Second, please connect with solar panel through DC side; Next please turn on AC side switch, you will find the red led lamp is lighting, then green LED lamp is flashing, final green LED lamp will stable lighting.
Remark: if the red LED lamp can' t turn off, and green L ED lamp will not appear. You need to take multi-meter to check they are within the allowed range or not.
5. Why when i get this inverter i can't see any color LED lamp lighting?
All inverter has been tested before packaged. Few inverter is dead for the long trip transport. If buyer can't find any L ED lamp lighting, please check both DC and AC sides connecting and workable? If yes, please contact with us through email: [email protected] , we will guide you return progress.
6. Do I need to get approval from the government grid company to connect to local city grid net?
(1) Normal conditions are not required. Because the current generated by this product is very small, it will not cause any impact on the local power grid.
(2) However, the local government or the power company has regulations or can not be connected. It is recommended that you choose the inverter with limited current function from our company (please consult sales).
7. Can i directly use battery as power supplier to connect with my local grid net?
(1) Yes, but battery voltage is stable changing when working. The MPPT function of this inverter can’t be used.
(2) Meanwhile, please take care for the voltage must be matched with your inverter. Please note that the positive and negative poles cannot be reversed, otherwise inverter will be damaged.
8. How can i know its working situation?
First, you can inspect its LED situation. If no lighting, that means the inverter doesn't be started, the reason many be; DC or AC side doesn't be connected in well, you can use multimeter to test both sides;
Second, if the light in red, that means there is fault or some protection has been activated (Please read the description of the LED light in detail);
Third, if the L ED in green but unstable. That means the DC or AC voltage is too low. Maybe the sunlight not strong to output the enough voltage to inverter. Or your local city grid voltage is unstable;
Fourth, if the green light is stable, no flash. It means your inverter in good working now.
Supply Ability
--
Packaging and Shipping
Lead time
--