6KVA Carspa Hybrid Mppt Solar Power Inverter with controller, battery charger
- Minimal order
- 100 pieces
Message Phone call
Product Specifications
--
Product Description
Overview
Quick Details
Brand Name: SAKO
Model Number: SUNMAX 6KW
Input Voltage: 24V/48V
Output Voltage: 120V OR 230VAC
Output Current: 60A
Output Frequency: 50HZ60HZ
Output Type: Multiple
Size: 608X219X304MM
Type: DC/AC Inverters
Inverter Efficiency: 88%
Certificate: CE
Warranty: 5
Weight: 53KG
Specification: Normal
Solar Panel Type: Grade A Polycrystalline
Input Voltage (VDC): 48VDC
Input AC Range (VAC): 165VAC±4% - 265VAC±4%
Frequency Range (Hz): 57Hz or 60Hz (47Hz-53Hz for 50Hz)--(57Hz-63Hz for 60Hz)
AC Efficiency: > 95%
Charge Mode Input Voltage Range: 165VAC±4% - 265VAC±4%
Output Voltage (VAC): 230VAC (Pure Sine Wave)
Inversion Efficiency: > 88%
Load Power (W): 6KW
Supply Ability
Supply Ability: 10000 Piece/Pieces per Month Solar Inverter
Packaging & Delivery
6KVA Carspa Hybrid Mppt Solar Power Inverter with controller, battery charger
1.Real MPPT charge controller built inside,15%-20% higher than PWM charge controller, use solar utmost.
2.The charge controller will auto start or stop working according to the sunshine status, the night power consumption < 1W.
3.User can set up the charge current, voltage and the working mode as needs.
4.Pure sine wave, excellent load adaptability, can load different types of heavy load such as air conditioner,refrige and small pumps.
5.Big copper transfomer built inside, isolated output, 100% real power, durable and safe. 6.Besides MPPT solar charger, built with big AC charger inside, ensure the power supply at night or continuous cloudy/rainny days. 6.Different types of battery selection to get the best charge voltage and mode, good for the battery service life.
7.Big LCD display plus buzzer alarms Design, show every information crealy. User can know the working status at glance.
8.Intelligent battery management, 3 stages of battery charging and all around protection functions. Exctent battery life
9.Auto switch and auto charging, achives unattendtion operation.
10.All around protection: Over load,short circuit protection,Over charge,discharge protection,Low battery and high protection.
11.Temperature controlled fan, full automatic and silent operation.
12.Compatible with generator, both generator and grid power can be extra backup
MODEL | SUNMAX 1KW | SUNMAX 2KW | SUNMAX 3KW | SUNMAX 4KW | SUNMAX 5KW | SUNMAX 6KW | ||||||
SPECIFICATION | ||||||||||||
DC INPUT | ||||||||||||
Input Voltage(Vdc) | 12V/24V | 24V/48V | ||||||||||
Min DC start voltage(Vdc) | 10V/20V | 20V/40V | ||||||||||
AC Bypass | ||||||||||||
Nominal Input Voltage | 110V or 230Vac (Waveform: Sine wave or as generator) | 230Vac(Waveform: Sine wave or as generator) | ||||||||||
Input AC Range(Vac) | 90Vac±4%-135Vac±4% or 184Vac±4%-253Vac±4% | 184Vac±4%-253Vac±4% | ||||||||||
Frequency Range(HZ) | 57Hz or 60Hz (47Hz-53Hz for 50Hz, 57Hz-63Hz for 60Hz) | |||||||||||
Input Frequency(Hz) | 50Hz/60Hz (Auto detection) | |||||||||||
Bypass Output Voltage(Vac) | Same as input voltage | |||||||||||
Bypass Output Frequency(Hz) | Same as input frequency | |||||||||||
Max Bypass Overload Current | 10A | 30A | 40A | |||||||||
AC Efficiency | > 95% | |||||||||||
Transfer Time(ms) | 20ms (typical) | |||||||||||
MPPT CHARGE CONTROLLER BUILT INSIDE | ||||||||||||
The rated charge current (A) | 40A | 40A | 50A | 50A | 60A | 60A | ||||||
Max PV input voltage( Vdc) | ≤150Vdc | |||||||||||
The battery voltage (Vdc) | 12V/24V/48V Auto identify and adaptive | |||||||||||
Battery types for selection | Lead Acid/Gel/Flood battery/Activated the sleeping of damaged batteries | |||||||||||
Fast charge voltage( vdc) | 14.0V for 12V system/28V for 24V system/56V for for 48V system | |||||||||||
Float Charge Voltage(Vdc) | 13.8V for 12V system/27.6V for 24V system/55.2V for 48V system | |||||||||||
Over charge Protection Vol.(Vdc) | 15V for 12V system/30V for 24V system/60V for 48V system | |||||||||||
Over charge Recovery Vol.(Vdc) | 13.6V for 12V system/27.2V for 24V system/54.4V for 48V system | |||||||||||
CHARGER | ||||||||||||
Charge mode Input Voltage Range | 80~145Vac or 95~255Vac | 100~255Vac | ||||||||||
Automatic Charge mode | Three stage charge mode:Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage) | |||||||||||
Nominal Charge Voltage | According to the battery type setup | |||||||||||
Charge Current(A) | 17.5A/35A/70A | |||||||||||
Charge boost voltage(v) | According to the battery type setup( 12V BAT:14-15.5v 24V BAT: 28-31V 48V BAT:56-62V ) | |||||||||||
Charge Floating Voltage(V) | According to the battery type setup (12V BAT: 13.3-13.7, 24v BAT: 26.6-27.6, 48V BAT:53.2-55.2V ) | |||||||||||
Over Charge Protection | Bat. V ≥15.7Vdc, beeps 0.5s every 1s & fault after 60s (15.7 for 12v, 31.4V for 24V, 62.8V for 48V ) | |||||||||||
Charger Short Circuit Protection | Circuit breaker | |||||||||||
(INVERTER) | ||||||||||||
Capacity(VA) | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | ||||||
Output Power(W) | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | ||||||
Power Factor(PF) | 1 | |||||||||||
Output Voltage | 120V or 230Vac (Sine wave ) | 230Vac (Sine wave ) | ||||||||||
Output Frequency | 50/60 ± 0.3Hz(auto tracking main first power connection) | |||||||||||
Wave | pure sine wave | |||||||||||
Inversion Efficiency | >88% | |||||||||||
Over load capacity | (110%<load<125%) ±10%: Fault (shutdown output) after 15 minutes; (125%<load<150%) ±10%: Fault (shutdown output) after 60s; Load>150% ±10%: Fault (shutdown output) after 20s | |||||||||||
Low Battery Alarm | 10.5Vdc ± 0.3Vdc for 12V battery, 21.0Vdc ± 0.6Vdc for 24V battery, 42.0Vdc ± 1.2Vdc for 48V battery | |||||||||||
Power saver | Load 25W | |||||||||||
AMBIENT | ||||||||||||
Noise(dB) | 60dB max. | |||||||||||
Temperature | 0°C to 40°C | |||||||||||
Humidity | 5% to 95% | |||||||||||
Sea Level(m) | ≤1500 | |||||||||||
DIMENSION | ||||||||||||
Product size L×W×H(mm) | L488mm*W219mm*H304mm | L608mm*W219mm*H304mm | ||||||||||
Packing size | L617mm*W312mm*H385mm | L760mm*W312mm*H385mm | ||||||||||
Weight(Kg) | 23/24.5 | 24.5/26 | 30.5/31.5 | 38.8/40.8 | 43.5/45.5 | 50.5/52.5 |
new products
other Products
Company Information
Certifications
Packaging & Shipping
FAQ
Q1: How to choose a right inverter?
A1:Tell us your demand, then our sales will recommend a suitable inverter to you.
Q2: What's the different between inverter and solar inverter?
A2: Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accept PV input, it more save power.
Q3: How about the delivery time?
A3: 7 days for sample; 25 days for bulk order.
Q4: What is the warranty of inverter?
A4: One year warranty on SAKO-Solar product.
Q5: How to solve the technical problem?
A5: 24 hours after-service consultancy just for you and to make your problem to solve easily.
Contact us
Supply Ability
--
Packaging and Shipping
Lead time
--
Port
--