5kw power inverter 220v/48v any power combi inverter mppt solar inverter 5kva
- Minimal order
- 100 pieces
Message Phone call
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin: Guangdong, China
Brand Name: YIY
Model Number: APV-5000W
Output Power: 1 - 200KW
Input Voltage: 120VAC/230VAC
Output Voltage: 24V/48V
Output Current: 15A-100A
Output Frequency: 50HZ/60HZ
Output Type: Single
Size: 530*240*390mm
Type: DC/AC Inverters
Weight: 50KG
COLOR: BLACK
POWER: 1KW~6KW
INPUT VOLTAGE: 24VDC
OUTPUT VOLTAGE: 110V/220V
BATTERY TYPES: nine types
FREQUENCY: 50hz/60hz
THD: <10%
MAX CHARGE CURRENT: 70A
NOMINAL EFFICIENCY: 88%
WAVE FORM: pure sine wave
Supply Ability
Supply Ability: 5000 Piece/Pieces per Month Power Inverter
Packaging & Delivery
We are Inverter industry leader !
Product Dominance
APV Series Pure Sine Wave Inverter & Charger & Solar Charger
APV solar charger is a combination of AP inverter and solar charger. The APV pure sine wave inverter not only makes your solar system simple in wiring, but also has all the unique features from the inverter and solar charger.
Feature of APV Series Inverter & Charger & Solar Charger
- Note:*For 1KW one. **For some models.
Product Parameter
Electrical Specifications | |||||||
Model | APV 1000W | APV 2000W | APV 3000W | APV 4000W | APV 5000W | APV 6000W | |
Output (Inverter Mode) | Continuous Output Power | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W |
Surge Rating | 3000W | 6000W | 9000W | 12000W | 15000W | 18000W | |
Output Waveform | Pure sine wave/same as input(bypass mode) | ||||||
Nominal Efficiency | >88%(peak) | ||||||
Line Mode Efficiency | >95% | ||||||
Power Factor | 0.9-1.0 | ||||||
Nominal Output Voltage rms | 120/230VAC | ||||||
Output Voltage Regulation | ±10% rms | ||||||
Output Frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | ||||||
Short Circuit Protection | Yes( 10s after fault ) | ||||||
Typical Line Stansfer Time | 10ms(max.) | ||||||
THD | <3% | ||||||
DC Input | Nominal Input Voltage | 12V | 24V | 48V | |||
Minimum Start Voltage | 10V | 20V | 40V | ||||
Low Battery Alarm | 10.5V | 21V | 42V | ||||
Low Battery Trip | 10V | 20V | 40V | ||||
High Voltage Alarm | 16V | 32V | 64V | ||||
Low Battery Voltage Recover | 13V | 26V | 52V | ||||
Idle Consumption- Search Mode | < 25W when power saver on | ||||||
AC Charger | Input Voltage Range | 95-127VAC | 194-243VAC | 164-243VAC(W) | |||
Output Voltage | Depends on battery type | ||||||
Max Charge Rate | 35A / 70A | ||||||
Battery Initial Voltage for Start Up | 0-15.7V for 12V( *2 for 24V, *4 for 48V) | ||||||
Over Charge Protection Shutdown | 15.7V for 12V (*2 for 24V, *4 for 48V) | ||||||
Charger curve(4 stage constant current), battery types 4 step digital controlled progressive charge | |||||||
Battery type | Fast V, float V ( *2 for 24v, *4 for 48v) | ||||||
Gel U.S.A | 14 | 13.7 | |||||
A.G.M 1 | 14.1 | 13.4 | |||||
A.G.M 2 | 14.6 | 13.7 | |||||
Sealed Lead Acid | 14.4 | 13.6 | |||||
Gel Euro | 14.4 | 13.8 | |||||
Open Lead Acid | 14.8 | 13.3 | |||||
Calcium | 15.1 | 13.6 | |||||
De-sulphation | 15.5 for 4hrs | ||||||
Remote Control | Yes. Optional | ||||||
Bypass & Protection | Input Voltage Waveform | Sine wave (grid or generator) | |||||
Nominal Voltage | 120VAC | 230VAC | |||||
Low Voltage Trip | 90V±4% | 184V/154V±4% | |||||
Low Voltage Re-engage | 100V±4% | 194V/164V±4% | |||||
High Voltage Trip | 140V±4% | 253V±4% | |||||
High Voltage Re-engage | 135V±4% | 243V±4% | |||||
Max. Input AC Voltage | 150VAC | 270VAC | |||||
Nominal Input Frequency | 50Hz or 60Hz (auto detect) | ||||||
Low Freq Trip | 47Hz± 0.3Hz for 50Hz, 57Hz± 0.3Hz for 60Hz | ||||||
Low Freq Re-engage | 48Hz± 0.3Hz for 50Hz, 58Hz± 0.3Hz for 60Hz | ||||||
High Freq Trip | 55Hz± 0.3Hz for 50Hz, 65Hz± 0.3Hz for 60Hz | ||||||
High Freq Re-engage | 54Hz± 0.3Hz for 50Hz, 64Hz± 0.3Hz for 60Hz | ||||||
Overload Protection | Circuit breaker | ||||||
Short Circuit Protection | Circuit breaker | ||||||
Transfer Switch Rating | 30amp | 40amp | |||||
Bypass Without Battery Connected | Yes | ||||||
Max. Bypass Current | 30amp | 40amp | |||||
Bypass Over Load Current | 35amp: alarm | 45amp: alarm | |||||
Solar Charger | Rated Voltage | 12V | 24V | ||||
Rated Charge Current | 40A | ||||||
Rated Output Current | 15A | ||||||
Self Consumption | < 10mA(at idle) | ||||||
Bulk Charge | 14.5V(default) | 29.0V(default) | |||||
Floating Charge | 13.5V(default) | 27.0V(default) | |||||
Equalization Charge | 14.0V(default) | 28.0V(default) | |||||
Over Charge Disconnection | 14.8V | 29.6V | |||||
Over Charge Recovery | 13.6V | 27.2V | |||||
Over Discharge Disconnection | 10.8 V(default) | 21.6V(default) | |||||
Over Discharge Reconnection | 12.3V | 24.6V | |||||
Temperature Compensation | -13.2mV/°C | -26.4mV/°C | |||||
Ambient Temperature | 0-40°C(full load) 40-60°C(derating) | ||||||
Mechanical Specifications | |||||||
Mounting | Wall mount | ||||||
Inverter Dimensions(L*W*H) | 598*218*179mm | 470*190*340mm | |||||
Inverter Weight | 21KG | 23KG | 27KG | 38KG | 48KG | 48KG | |
Shipping Dimensions(L*W*H) | 740*315*300mm | 530*240*390mm | |||||
Shipping Weight | 23KG | 25KG | 29KG | 40KG | 50KG | 50KG | |
Display | Status LEDs / status LEDs+LCD | ||||||
Standard Warranty | 1 year |
Parameter of Solar Charger
Electrical Specvifications | ||||||||||||||||||
Model | APV 1000W | APV 1500W | APV 2000W | APV 3000W | APV 4000W | APV 5000W | APV 6000W | |||||||||||
Output (Inverter mode) | Continuous Output Power | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | ||||||||||
Surge Rating | 3000W | 4500W | 6000W | 9000W | 12000W | 15000W | 18000W | |||||||||||
Output Waveform | Pure Sine wave/Same as input(Bypass mode) | |||||||||||||||||
Nominal Efficiency | >88%(Peak) | |||||||||||||||||
Line Mode Efficiency | >95% | |||||||||||||||||
Power Factor | 0.9-1.0 | |||||||||||||||||
Nominal Output Voltage rms | 100-110-120Vac / 220-230-240Vac | |||||||||||||||||
Output Voltage Regulation | ±10% RMS | |||||||||||||||||
Output Frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | |||||||||||||||||
Short Circuit Protection | Yes( 1sec after fault ) | |||||||||||||||||
Typical Line Stansfer Time | 10ms(MAX) | |||||||||||||||||
THD | <10% | |||||||||||||||||
DC Input | Nominal Input Voltage | 12.0Vdc | ||||||||||||||||
( *2 for 24Vdc, *4 for 48Vdc) | ||||||||||||||||||
Minimum Start Voltage | 10.0Vdc | |||||||||||||||||
Low Battery Alarm | 10.5Vdc / 11.0Vdc | |||||||||||||||||
Low Battery Trip | 10.0Vdc / 10.5Vdc | |||||||||||||||||
High Voltage Alarm | 16.0Vdc | |||||||||||||||||
Low Batteryvoltage recover | 15.5Vdc | |||||||||||||||||
Idle Consumption- Search Mode | < 25 W when Power Saver On | |||||||||||||||||
AC Charger | Input Voltage Range | Wide: 90~135VAC / 164~243VAC; Narraw: 100~135VAC / 194~243VAC; | ||||||||||||||||
Output Voltage | Depends on battery type | |||||||||||||||||
Max Charge Rate | 35A / 70-90A Max (Charger Current Control) | |||||||||||||||||
Battery InitialVoltagefor Start Up | Circuit breaker | |||||||||||||||||
Over ChargeProtection Shutdown | 15.7V for 12V( *2 for 24Vdc, *4 for 48Vdc) | |||||||||||||||||
Charger curve (4 stage constant current) 4 step digital controlled progressive charge | Battery types ( *2 for 24Vdc, *4 for 48Vdc) | |||||||||||||||||
Battery type | Fast V Float V( *2 for 24Vdc, *4 for 48Vdc) | |||||||||||||||||
Gel U.S.A | 14.0 | 13.7 | ||||||||||||||||
A.G.M 1 | 14.1 | 13.4 | ||||||||||||||||
A.G.M 2 | 14.6 | 13.7 | ||||||||||||||||
Sealed Lead Acid | 14.4 | 13.6 | ||||||||||||||||
Gel Euro | 14.4 | 13.8 | ||||||||||||||||
Open Lead Acid | 14.8 | 13.3 | ||||||||||||||||
Calcium | 15.1 | 13.6 | ||||||||||||||||
De-sulphation | 15.5 for 4hrs | |||||||||||||||||
Remote Control | Yes. Optional | |||||||||||||||||
Bypass & Protection | Input Voltage Waveform | Sine wave (Grid or Generator) | ||||||||||||||||
Nominal Voltage | 120VAC / 230VAC | |||||||||||||||||
Low Voltage Trip | 90V±4%/184V/154V±4% | |||||||||||||||||
Low Voltage re engage | 100V±4%/194V/164V±4% | |||||||||||||||||
High Voltage Trip | 140V±4%/ 253V±4% | |||||||||||||||||
High Voltage re engage | 135V±4%/243V±4% | |||||||||||||||||
Max Input AC Voltage | 150VAC/270VAC | |||||||||||||||||
Nominal Input Frequency | 50Hz or 60Hz (Auto detect) | |||||||||||||||||
Low freq trip | 47Hz± 0.3Hz for 50Hz, 57Hz± 0.3Hz for 60Hz | |||||||||||||||||
Low freq re engage | 48Hz± 0.3Hz for 50Hz, 58Hz± 0.3Hz for 60Hz | |||||||||||||||||
High freq trip | 55Hz± 0.3Hz for 50Hz, 65Hz± 0.3Hz for 60Hz | |||||||||||||||||
High freq re engage | 54Hz± 0.3Hz for 50Hz, 64Hz± 0.3Hz for 60Hz | |||||||||||||||||
Overload protection | Circuit breaker | |||||||||||||||||
Short circuit protection | Circuit breaker | |||||||||||||||||
Transfer switch rating | 30amp | 40amp | ||||||||||||||||
Max bypass current | 30amp | 40amp | ||||||||||||||||
Bypass over load current | 35amp: Alarm | 45amp: Alarm | ||||||||||||||||
Solar Charger | Rated Voltage | 12V/24V/48V | ||||||||||||||||
Rated Charge Current | 40A/60A | |||||||||||||||||
Rated Output Current | 15A | |||||||||||||||||
Self Consumption | < 10mA | |||||||||||||||||
Bulk Charge | 14.5V(default) | ( *2 for 24Vdc, *4 for 48Vdc) | ||||||||||||||||
Floating Charge | 13.5V(default) | |||||||||||||||||
Equalization Charge | 14.0V(default) | |||||||||||||||||
Over Charge Disconnection | 14.8V | |||||||||||||||||
Over Charge Recovery | 13.6V | |||||||||||||||||
Over Discharge Disconnection | 10.8 V(default) | |||||||||||||||||
Over Discharge Reconnection | 12.3V | |||||||||||||||||
Temperature Compensation | - 13.2mV/°C | |||||||||||||||||
Ambient Temperature | 0-40°C(full load) 40-60°C(derating)
|
Function Contrast
Company Information
Zhejiang Yiyuan Electric Co., Ltd.
|
|--- Headquarters: add:WenZhou produce voltage stabilizer
|
|--- Branch:add:ShenZhen produce Inverter
|
|--- Found in 2008, Sales:12 worker: 150 engineer : 10
|
|--- 10% of profit use for advancement and innovation
|
|--- Have CE, TUV, FCC, PCT and ISO9001 certificates
|
|--- Market:Russia, Southeast Asia, Africa, Mid-east regions, North America
FAQ
Q 1. what's the payment term?
A. We accept TT,30% deposit and 70% balance agaisnt copy of BL
Q 2. how's the delivery time ?
A. usually it will take about 25 days for production
Q 3. tell me the standard of package?
A. For the small capacity, it use carton, but for big capacity, we should use strong wooden case for protection.
Q 4. what kind of material of transformer?
A. we have two types, one 100% copper and the other is copper with aluminum.It depends on your requirment. In fact,those two have no difference if normal work well. Only except the longlife. Copper is better and also higer price.
Q 5.Could you offer Form A or C/O ?
A. It totally not a problem. We can prepare relative documents to forgin affairs office or other office to apply for this certificate.
Q 6.Would you accept to use our logo ?
A.If you have good quantity,it absolute no problem to do OEM.
Q 7.We want to know month capacity.
A. It depends on which model.For example for relay type small capacity , month capacity can reach near 20000pcs and big capacity near 3000pcs.
Q 8.Where is your market?
A. Our products are popular in russia, indonisia, Philippines,italy, america, pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q 9.Does the inverter connect with solar system ?
A.Yes.Because of the unique feature which combine invert,charge and AC auto-transfer switch into one complete system,made inverter not only connect with solar system,also could be used in& officer equipment,household items,power tools ans etc..
Q10. what kind of certificate you have ?
A. Our company already achieve ISO, CCC, and for products, we have CE, SONCAP, GOST, UL(pending) .
Supply Ability
--
Packaging and Shipping
Lead time
--
Port
--
Packaging details
--