48V Battery 60A Solar Charge Discharge Controller for Solar System with LCD Display Cm6048
60A 48V
CM series controller is a kind of intelligent, multi-purpose solar charge and discharge controller. The family use the fixed LCD display, with a very friendly interface; various control parameters can be flexibly set, fully meet your various application requirementsSpecification
Model | CM6048(CM6048Z) |
Rated Current | 60A |
Rated Voltage | 48V |
Maximum Voltage of Solar panel | 100V |
Float Voltage | 54.8V |
Low Voltage Disconnection | 42.8V |
Low Voltage Reconnection | 50.4V |
No load loss | <30mA |
Loop Voltage Drop | <200mV |
Charging Mode | PMW Mode |
Temperature Compensation | -4mV/Cell/ºC |
Notes | Model suffix "Z" represent automatic identify system voltage level "T" represent controller with remote monitoring |
Main Features
ystem | 48V |
Max PV Input Power | 2880W |
Max PV Input Voltage | 72V |
Battery Voltage | 48V |
Load Output Current | 60A |
Connection Order:
1.Connect the battery with the controller.
2.Connect the solar panel with the controller.
3.Connect the load with the controller or inverter.
Disconnection order:
1.Disconnect the solar panel.
2.Disconnect the battery.
3.Disconnect the load.
Precautions:
1.please make sure connect your inverter with your battery
2.Please avoid to install in the following environments wet,dusty places or places with flammable and explosive gases.
3.Install the controller at the vertical plane.
Instructions
CM series controller is a kind of intelligent, multi-purpose solar charge and discharge controller. The family use the fixed LCD display, with a very friendly interface; various control parameters can be flexibly set, fully meet your various application requirements. CM series controller has following features:
1.Image of LCD graphic symbol
2.Automatic Identification System Voltage level
3.Automatic Temperature Compensation
4.Settable Operating mode of Load
5.Remote monitoring and control function (custom)
6.Battery Low Voltage Disconnection (LVD)
7.Accumulated function of charge and discharge Ampere hours
8.Simple button operation
9.Intelligent PWM charge mode
10.Adjustable charge-discharge control parameters
11.Overload, Short Circuit Protection
12.Battery reverse-discharge protection
13.Battery reverse connection protection
Battery Voltage,
Battery temperature,
Solar Panel charge current,
Accumulated discharging power(Ah),
Accumulated charing power(Ah),
Load discharge current
FAQs:
1.LVD Protection and Treatment
Screen display as shown in the figure that the battery drops below the LVD protection voltage. The controller has entered the LCD protection state, load circuit has been disconnected. Use the solar panels recharge the battery or charger when the battery voltage reaches LVR voltage, the controller will resume on the load power supply, into the normal working state.
2.Solar Panel Fault and Treatment
Symbol flashing represent the controller was not detected solar panels within 24hours. Check if there is a connection from solar panel, check if there is an open circuit between solar panels with controller.
Install
1) Ready tools and cables. Encourage you to matching the right cables. Ensure that the current density 4mm2 that is conductive to reducing the line voltage drop. Recommended: 50A with 16mm2 cable. Check weather the installation sites compliance with the relevant safety requirements. Please avoid the damp, dusty, there is a place flammable, explosive and corrosive gases use the controller to install.
2) Install the controller into a fixed vertical plane. See section 5 of the pore size and pore spacing. In order to ensure a good thermal control conditions, please set aside each 10cm below the controller space.
3) As shown on the right, connect the (1) Load,(2) Battery and (3) Solar Panel to the controller according to the order of (1) (2) (3). Pay attention to the load, battery, solar panel and controller of same polarity.
4) Put into the external temperature sensor on the left of the controller (probe port). The temperature sensor should be similar space with battery. (Otherwise, the controller will control the parameters of all wrong temperature compensation.)
5) If you have remote monitoring and control function, please insert one end of the included communication wire on the right of the controller (communication port), the other end to connect to The host computer.
Demolition: To prevent accidents, please order the demolition of solar panels, battery and load disconnect with controller.
Note: Battery polarity will not damage the controller, but you will have a load equipment security risks.
Supply Ability
--
Packaging and Shipping
Lead time
--
Port
--
Packaging details
--